Campbell Scientific RAWS-F station. All sensors calibrated/replaced before each campaign. GPS receiver used for GPS clock synchronization and location logging. The sensors were measured every second with the exception of 10 hour fuel stick moisture which was measured once an hour to conserve battery power. Logging of post processed measurements (average, standard deviation, totalizing) occurred over the 60 second time interval prior to the logged time. Campbell Scientific Sensors CS516-QD fuel moisture/temperature sensor WindSonic4-QD 2-D Sonic Wind Sensor CS100-QD Barometric Pressure Probe TE525-MM Tipping Bucket Rain Gage HygroVue10 Air Temperature and Relative Humidity Probe CS301 Apogee SP-110-SS Pyranometer GPS16X-HVS global positioning system (GPS) receiver Station was programmed to measure every second, log every minute. 10 hour fuel moisture was logged every hour. For the Fort Stewart 2024 Campaign, the station was deployed in a central location and not moved.